For almost every application requirement we offer
a suitable sensor including the necessary integration equipment.
With insertion capabilities into tube sizes down to 1mm (1/8”),
and with integrated temperature measurement it is very easy to meet
the general application recommendations.
Your advantages
|
| |
- Tough, completely encapsulated sensor
design
- Proprietary high-power technology for reliable results
even with high gas bubble concentrations
- Wide operating temperature
and pressure ranges up to 200°C
(392 ¡F) and up to 500 bar (7,250 psi)
- Additional options
like flow detector or wet/dry detection
- Digital sensor concept
ensures high precision results, low response time and fail
safe data transmission
- On-line presentation of the high-frequency
sonic signal shape (SonicGraph) allows optimal system set-up
|
| |
|
| |
 |
 |
The selection guide helps in choosing
the most suitable sensor design for your application |
|
| |
|
| |
General
purpose sensor for all applications in classified areas |
 |
| |
 |
Operating temperature
range: -10°C to +200°C or 14°F to
392°F
Rated pressure: -1 to 500 bar or –14.5 to 7,250 psi
Approval: ATEX, CE
Wetted parts material: 1.4571,Hastelloy, Monel, TiPd, gold plating,
electro polished
Line fittings: All flanges manufactured according to specifications
of DIN, ISO, ANSI and JIS starting with DN50 or 2"
Accessories: Immersion adapters for line sizes beginning with DN1
or 1/8”

|
| |
|
| |
General
purpose sensor for all applications in non-classified areas |
 |
| |
 |
Operating temperature range: -10°C
to +200°C or 14°F to 392 °F
Rated pressure: -1 to 500 bar or –14.5 to 7,250 psi
Approval: CE
Wetted parts material: 1.4571, Hastelloy, Monel, TiPd, gold plating,
electro polished
Line fittings: All flanges manufactured according to specifications
of DIN, ISO, ANSI and JIS starting with DN50 or 2”
Accessories: Immersion adapters for line sizes beginning with DN1
or 1/8”

|
| |
|
| |
Sensor
for sanitary applications with design and process fittings according
to FDA, 3A standards and EHEDG recommendations |
 |
| |
 |
Operating temperature range: -10°C
to +150°C or 14°F to 302°F
Rated pressure: -1 to 24 bar or –14.5 to 348 psi
Approval: CE
Wetted parts material: 1.4571, electro polished
Line fittings: Varivent, tri-clamp, all flanges according to DIN,
ISO, ANSI and JIS specifications starting with DN50 or 2”
Accessories: Immersion adapters for line sizes beginning with DN1
or 1/8”

|
| |
|
| |
Sensor
with PFA inlay for applications in the semiconductor industry and
in highly aggressive process liquids |
 |
| |
 |
Operating temperature range: 20°C
to +90°C or 68°F to 194°F
Rated pressure: -1 to 5 bar or –14.5 to 72.5 psi
Approval: CE
Wetted parts material: PFA
Line fittings: sandwich flange, thread adapter
Accessories: Immersion adapters for line sizes beginning with DN1
or 1/8”

|
| |
|
| |
Immersion
type sensor with separate electronics and variable immersion length
for Mini-plant and lab applications |
 |
 |
 |
Operating temperature range: -10°C
to +150°C or 14°F to 302°F
Rated pressure: -1 to 24 bar or –14.5 to 348 psi
Approval: CE
Wetted parts material: 1.4571, Hastelloy, Monel, TiPd, gold plating,
electro polished
Line fittings: Varivent, tri-clamp, all flanges according to DIN,
ISO, ANSI and JIS specifications starting with DN50 or 2”
Accessories: Immersion adapters for line sizes beginning with DN1
or 1/8”

|
 |
|