The immersion sensor with separated electronic housing is used as standard in confined installation situations, strong pipeline vibrations, or ambient temperatures above 50 °C.
Parameter
Value
Material temperature
-20 °C to 120 °C (CIP-suitable up to 150 °C)
Pressure
16 bar
Sensor materials
Stainless steel DIN 1.4404
Process connection
variable
Housing
Stainless steel housing (IP68) or Aluminum die-cast housing (IP65)